RealCare Baby® 4 Electronics Board Replacement Instructions
Thank you for working with us to ensure your RealCare Baby 4(s) are working properly. Inside this package is an electronics board for each of your infant simulators affected by this technical issue. We sincerely apologize for the inconvenience!
Please use the contents of this package to replace the electronics board of your RealCare Baby 4(s).
Replacement package contents:
- Per Baby:
- New electronics board
- New Baby wristband
- 4 cable ties
Control Center Deleting a Baby (0:45):
Replacing Batteries and Electronics (3:50):
- Use the Instructor Key to remove the battery cover on the back of your Baby.
- Unscrew the two screws that secure the electronics board to the Baby. Do not discard the screws.
- Gently pull the old electronics board out of the Baby.
- Cut the cable ties on the old electronics board to remove the batteries.
- Insert the plugs on the batteries into the sockets on the new electronics board.
- Secure the batteries to the new electronics board with the new cable ties.
- Cut the excess length of each cable tie
- Slide the new electronics board into the Baby.
- Secure the new electronics board with the two screws you removed in Step 2.
- Put the battery cover back on the Baby and secure it using the Instructor Key.
Replacing the Baby’s Wristband
- Cut off the Baby’s wristband and put the new one on Baby.
- Tighten the wristband and remove the adhesive-backed divider.
- Secure the wristband.
Adding to Control Center and Programming (20:50):
We sincerely apologize for any inconvenience this may have caused your program.
If you have questions, please don’t hesitate to contact us via email.